Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2
Engineering Breakdown: Running a Ventless All-in-One Washer & Heat Pump Dryer (120V) on the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank
When pairing the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank (10,240 Wh LiFePO4 capacity, 4,000 W continuous, 9,000 W surge) with a Ventless All-in-One Washer & Heat Pump Dryer (120V) (950 W running, 1,400 W starting surge), the system operates at 24% of continuous inverter capacity on a 120 V North American circuit and 24% on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 9.2 hrs of off-grid runtime. Wiring the connection over a 25 ft run calls for a 15 A breaker and 14 AWG copper, terminated at a NEMA 5-15P connection.
1. Compatibility Verdict & Inverter Load Utilization
In North American mode the Ventless All-in-One Washer & Heat Pump Dryer (120V) loads the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank's inverter to 24% of its 4,000 W continuous rating and 16% of its 9,000 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 3,050 W of spare capacity for lights, a router or a refrigerator on the same unit.
| Check | Load requires | Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank provides | US/NA | UK/EU/AU |
|---|---|---|---|---|
| Continuous output | 950 W | 4,000 W | Pass | Pass |
| Start-up surge | 1,400 W | 9,000 W | Pass | Pass |
| Voltage | 120 V / 230 V | 120 V / 230 V | Pass | Pass |
| Connection | NEMA 5-15P | Hardwired AC Distribution / L5-30R | UK/EU/AU: BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A | |
Compressor appliances such as refrigerators and freezers draw very little on average — 950 W while running — but need 1,400 W for a moment each time the compressor kicks on. Their duty cycle is typically 30–40%, which is why a modest battery can keep food safe for a long time. The Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank's 9,000 W surge rating comfortably handles each restart.
The Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank is a marine and RV inverter-charger. Its strength is power quality and PowerAssist blending with shore or generator input rather than standalone 240V output.
2. Real-World Runtime by Duty Cycle
Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 10,240 Wh rating to about 8,704 Wh of deliverable AC energy (85% system efficiency). Duty cycle is the share of each hour the load actually draws its running power — thermostats, pressure switches and intermittent use all lower it.
| Duty cycle | Average draw | Runtime (no solar) | Energy per 24 h |
|---|---|---|---|
| 25% | 238 W | 36.6 hrs | 5.7 kWh |
| 50% | 475 W | 18.3 hrs | 11.4 kWh |
| 65% | 618 W | 14.1 hrs | 14.8 kWh |
| 100% | 950 W | 9.2 hrs | 22.8 kWh |
Even at a 50% duty cycle the battery lasts 18.3 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.
3. NEC 125% Breaker & Copper Wire Gauge Sizing
NEC 210.19(A) and 210.20(A) require conductors and overcurrent devices for continuous loads — anything running three hours or more, which includes EV charging and HVAC — to be rated at 125% of the load current. For this pairing: 950 W ÷ 120 V = 7.9 A, × 1.25 = 9.9 A, which rounds up to the next standard NEC 240.6 size of 15 A. The conductor must be protected by that breaker (75 °C ampacity at least 15 A) and keep round-trip voltage drop at or below 3%, so longer runs are upsized.
Voltage drop % = (2 × L × I × R) ÷ V × 100
North America (NEC, THHN copper, 75 °C)
| One-way distance | Breaker | Min. copper | Voltage drop | Note |
|---|---|---|---|---|
| 25 ft (7.6 m) | 15 A | 14 AWG | 1.01% | Sized by ampacity |
| 50 ft (15.2 m) | 15 A | 14 AWG | 2.03% | Sized by ampacity |
| 75 ft (22.9 m) | 15 A | 12 AWG | 1.91% | Upsized for voltage drop |
| 100 ft (30.5 m) | 15 A | 12 AWG | 2.55% | Upsized for voltage drop |
UK / EU / Australia (IEC 60364 / BS 7671, PVC copper, method C)
IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 4.1 A, so a 6 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.
| One-way distance | MCB | Min. cable | Voltage drop |
|---|---|---|---|
| 7.5 m (25 ft) | 6 A | 1.5 mm² | 0.33% |
| 15 m (49 ft) | 6 A | 1.5 mm² | 0.65% |
| 22.5 m (74 ft) | 6 A | 1.5 mm² | 0.98% |
| 30 m (98 ft) | 6 A | 1.5 mm² | 1.30% |
Moving the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank from 25 ft to 100 ft away forces the conductor up from 14 AWG to 12 AWG — park the unit as close to the load as ventilation and weather protection allow.
4. Solar Array Recharge Time Breakdown
The Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank accepts up to 5,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).
| PV array | Real harvest | 0–100% recharge | Sun-days @ 4.5 PSH | Net with load @ 50% |
|---|---|---|---|---|
| 400 W | 320 W | 32.0 hrs | 7.1 | −155 W |
| 800 W | 640 W | 16.0 hrs | 3.6 | +165 W |
| 1,600 W | 1,280 W | 8.0 hrs | 1.8 | +805 W |
| 3,000 W | 2,400 W | 4.3 hrs | 0.9 | +1,925 W |
| 5,000 W | 4,000 W | 2.6 hrs | 0.6 | +3,525 W |
A typical 800 W portable array refills the battery in about 16.0 hrs of strong sun, while maxing out the 5,000 W input cuts that to 2.6 hrs. To fully offset the Ventless All-in-One Washer & Heat Pump Dryer (120V) at a 50% duty cycle (475 W average) during daylight you need roughly 600 W of panels, which this unit can accept.
5. Frequently Asked Questions
Can the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank run a Ventless All-in-One Washer & Heat Pump Dryer (120V)?
Yes. The Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank delivers 4,000 W continuous and 9,000 W surge, covering the Ventless All-in-One Washer & Heat Pump Dryer (120V)'s 950 W running and 1,400 W start-up draw at 24% inverter utilization.
How long will the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank run a Ventless All-in-One Washer & Heat Pump Dryer (120V)?
With 10,240 Wh of capacity and 85% inverter efficiency, expect about 9.2 hrs of continuous operation and 18.3 hrs at a 50% duty cycle. Adding solar input during the day extends this further.
What breaker and wire size do I need to connect a Ventless All-in-One Washer & Heat Pump Dryer (120V) to the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank?
In the US, 950 W at 120 V is 7.9 A; applying the NEC 125% continuous-load rule gives 9.9 A, so use a 15 A breaker and 14 AWG copper for runs up to 25 ft (1.0% voltage drop). In 230 V markets the load draws 4.1 A, protected by a 6 A MCB on 1.5 mm² cable for runs up to 7.5 m. Receptacle: NEMA 5-15P (US) or BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A (UK/EU/AU).
How long does it take to recharge the Victron MultiPlus-II 48/5000 + 10kWh LiFePO4 Bank with solar panels?
With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 16.0 hrs of peak sun (3.6 days at 4.5 peak-sun-hours). At its maximum 5,000 W solar input it drops to 2.6 hrs.
Methodology & safety note
Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.