Skip to content
GRIDSPEC
Verified Engineering Spec • IEC 60364 / BS 7671

Can the Selectronic SP Pro AU Off-Grid Inverter Run a Single-Burner Portable Induction Cooktop?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the Selectronic SP Pro AU Off-Grid Inverter (10,240 Wh) paired with the Single-Burner Portable Induction Cooktop.

Configure your system

800 W
7.6 m (25 ft)
50%
Source outlets
Hardwired consumer unit (RCBO protected)
Load connection
BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A
Verified Hardware Match

Check current bundle pricing for the Selectronic SP Pro AU Off-Grid Inverter plus a changeover switch kit for this setup.

As an Amazon Associate, we earn from qualifying purchases.

Verified Compatible

Selectronic SP Pro AU Off-Grid Inverter handles 1,800 W continuous and 1,850 W surge with headroom.

5,700 W of continuous capacity left for other circuits.

Continuous load
24%
Runtime (no sun)
9.7 hrs
50% duty · 85% inverter eff.
Solar recharge
16.0 hrs
3.6 sun-days at 800 W
Min. copper wire
1.5 mm²
0.6% drop @ 7.6 m
Overcurrent device
10A MCB
7.8A load × 1.00 = 7.8A
Live schematic & breaker sizing diagram 230V AC • IEC 60364
SOLAR PV INPUT 800 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER Selectronic SP Pro AU Off-Grid Inverter 10,240 Wh • 7,500 W 22,500 W surge • 120/240V 24% load 10A MCB 1.5 mm² Cu 7.8A @ 230V CONNECTED LOAD Single-Burner Portable Induction Cooktop 1,800 W running 1,850 W surge 230V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a Single-Burner Portable Induction Cooktop on the Selectronic SP Pro AU Off-Grid Inverter

UK/EU/AU: Verified Compatible 24% inverter utilization Sold in UK / EU / AU only

When pairing the Selectronic SP Pro AU Off-Grid Inverter (10,240 Wh LiFePO4 capacity, 7,500 W continuous, 22,500 W surge) with a Single-Burner Portable Induction Cooktop (1,800 W running, 1,850 W starting surge), the system operates at 24% of continuous inverter capacity on a 230 V UK/EU/AU circuit. At a 100% duty cycle and 85% inverter efficiency, a full battery delivers roughly 4.8 hrs of off-grid runtime. Wiring the connection over a 7.5 m run calls for a 10 A MCB and 1.5 mm² copper, terminated at a BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A connection.

1. Compatibility Verdict & Inverter Load Utilization

In UK/EU/AU 230 V mode the Single-Burner Portable Induction Cooktop loads the Selectronic SP Pro AU Off-Grid Inverter's inverter to 24% of its 7,500 W continuous rating and 8% of its 22,500 W surge rating. Both figures are under the 80% sustained-load guideline, so this is a comfortable, verified match with 5,700 W of spare capacity for lights, a router or a refrigerator on the same unit.

CheckLoad requiresSelectronic SP Pro AU Off-Grid Inverter providesUK/EU/AU
Continuous output 1,800 W 7,500 W Pass
Start-up surge 1,850 W 22,500 W Pass
Voltage 230 V 230 V Pass
Connection BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A Hardwired consumer unit (RCBO protected)

This appliance is predominantly resistive or electronically controlled: its 1,850 W start-up figure is within 3% of its 1,800 W running draw, so surge capacity is rarely the bottleneck. What matters is sustained output and energy: heating elements draw full power for as long as they are on, which drains a 10,240 Wh battery quickly. Running it during solar production hours is the most efficient strategy.

The Selectronic SP Pro AU Off-Grid Inverter is a heavy-duty off-grid inverter-charger built for rural properties, with a surge rating of 22,500 W — 3.0× its continuous output — designed to start bore pumps, workshop compressors and other large motors.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 10,240 Wh rating to about 8,704 Wh of deliverable AC energy (85% system efficiency). Duty cycle is the share of each hour the load actually draws its running power — thermostats, pressure switches and intermittent use all lower it.

Runtime (h) = (10,240 Wh × 0.85) ÷ (1,800 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 450 W 19.3 hrs 10.8 kWh
50% 900 W 9.7 hrs 21.6 kWh
65% 1,170 W 7.4 hrs 28.1 kWh
100% 1,800 W 4.8 hrs 43.2 kWh

Even at a 50% duty cycle the battery lasts 9.7 hrs, so plan on solar, grid or generator recharging for anything longer than an evening outage.

3. BS 7671 / IEC 60364 Breaker & Cable Sizing

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 7.8 A, so a 10 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 10 A 1.5 mm² 0.62%
15 m (49 ft) 10 A 1.5 mm² 1.24%
22.5 m (74 ft) 10 A 1.5 mm² 1.85%
30 m (98 ft) 10 A 1.5 mm² 2.47%

Because the current is modest, 1.5 mm² copper stays within the voltage-drop target all the way to 30 m.

4. Solar Array Recharge Time Breakdown

The Selectronic SP Pro AU Off-Grid Inverter accepts up to 8,000 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
800 W 640 W 16.0 hrs 3.6 −260 W
1,600 W 1,280 W 8.0 hrs 1.8 +380 W
3,000 W 2,400 W 4.3 hrs 0.9 +1,500 W
6,000 W 4,800 W 2.1 hrs 0.5 +3,900 W
8,000 W 6,400 W 1.6 hrs 0.4 +5,500 W

A typical 800 W portable array refills the battery in about 16.0 hrs of strong sun, while maxing out the 8,000 W input cuts that to 1.6 hrs. To fully offset the Single-Burner Portable Induction Cooktop at a 50% duty cycle (900 W average) during daylight you need roughly 1,150 W of panels, which this unit can accept.

5. Frequently Asked Questions

Can the Selectronic SP Pro AU Off-Grid Inverter run a Single-Burner Portable Induction Cooktop?

Yes. The Selectronic SP Pro AU Off-Grid Inverter delivers 7,500 W continuous and 22,500 W surge, covering the Single-Burner Portable Induction Cooktop's 1,800 W running and 1,850 W start-up draw at 24% inverter utilization.

How long will the Selectronic SP Pro AU Off-Grid Inverter run a Single-Burner Portable Induction Cooktop?

With 10,240 Wh of capacity and 85% inverter efficiency, expect about 4.8 hrs of continuous operation and 9.7 hrs at a 50% duty cycle. Adding solar input during the day extends this further.

What breaker and wire size do I need to connect a Single-Burner Portable Induction Cooktop to the Selectronic SP Pro AU Off-Grid Inverter?

At 230 V the load draws 7.8 A. Under BS 7671 / IEC 60364 the protective device must be at least the design current (Ib ≤ In ≤ Iz), so use a 10 A MCB with RCD protection on 1.5 mm² copper cable for runs up to 7.5 m (0.6% voltage drop). Connection: BS 1363 13A / Schuko CEE 7/4 / AS/NZS 3112 10A.

How long does it take to recharge the Selectronic SP Pro AU Off-Grid Inverter with solar panels?

With an 800 W array and an 80% real-world harvest factor, a full recharge takes about 16.0 hrs of peak sun (3.6 days at 4.5 peak-sun-hours). At its maximum 8,000 W solar input it drops to 1.6 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the UK/EU/AU verdict: compatible, conditional, not compatible.

Other loads on the Selectronic SP Pro AU Off-Grid Inverter

All 50 loads on the Selectronic SP Pro AU Off-Grid Inverter →

Other power stations for the Single-Burner Portable Induction Cooktop

Compare every source for this load →

More Kitchen & Home Appliances on the Selectronic SP Pro AU Off-Grid Inverter