Can the Anker SOLIX C1000 Run a BMW i4 / iX (Flexible Fast Charger 24A)?

Live runtime simulator, solar recharge calculator and NEC / IEC breaker & cable schematic for the Anker SOLIX C1000 (1,056 Wh) paired with the BMW i4 / iX (Flexible Fast Charger 24A).

Configure your system

600 W
25 ft (7.6 m)
100%
Source outlets
NEMA 5-20R
Load connection
NEMA 14-50P
EV range rate
≈ 18 mi (29 km) of range per hour of charging
Compatible 240V Alternative

EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) (7,200 W, 240V split-phase output) runs this load at 80% utilization.

As an Amazon Associate, we earn from qualifying purchases.

240V Split-Phase Required

BMW i4 / iX (Flexible Fast Charger 24A) needs a 240V split-phase circuit — the Anker SOLIX C1000 only outputs 120V.

Wattage also falls short: 5,760 W running / 5,760 W surge vs 1,800 W / 2,400 W.

Continuous load
320%
Runtime (no sun)
—
Needs 240V output
Solar recharge
2.2 hrs
0.5 sun-days at 600 W
Min. copper wire
10 AWG
0.6% drop @ 25 ft
Overcurrent device
30A Breaker
24.0A load × 1.25 = 30.0A
Live schematic & breaker sizing diagram 120/240V Split-Phase • NEC 125% Rule
SOLAR PV INPUT 600 W PV MC4 / XT60 · MPPT POWER SOURCE / INVERTER Anker SOLIX C1000 1,056 Wh • 1,800 W 2,400 W surge • 120V 320% load 30A OCPD 10 AWG Cu 24.0A @ 240V CONNECTED LOAD BMW i4 / iX (Flexible Fast Charger 24A) 5,760 W running 5,760 W surge 240V load

Engineering report · reviewed against NEC 2026 & BS 7671:2018+A2

Engineering Breakdown: Running a BMW i4 / iX (Flexible Fast Charger 24A) on the Anker SOLIX C1000

US/NA: 240V Split-Phase Required UK/EU/AU: Continuous Overload 320% inverter utilization

When pairing the Anker SOLIX C1000 (1,056 Wh LiFePO4 capacity, 1,800 W continuous, 2,400 W surge) with a BMW i4 / iX (Flexible Fast Charger 24A) (5,760 W running, 5,760 W starting surge), the system operates at 320% of continuous inverter capacity on a 240 V North American circuit and 307% on a 230 V UK/EU/AU circuit. Our North American verdict is 240V Split-Phase Required, so the runtime figures below are theoretical battery-energy values only. Wiring the connection over a 25 ft run calls for a 30 A breaker and 10 AWG copper, terminated at a NEMA 14-50P connection.

1. Compatibility Verdict & Inverter Load Utilization

In North American mode the BMW i4 / iX (Flexible Fast Charger 24A) loads the Anker SOLIX C1000's inverter to 320% of its 1,800 W continuous rating and 240% of its 2,400 W surge rating. The blocking issue is voltage, not just wattage: the load requires a 240 V split-phase supply while this unit outputs 120 V only. The leanest compatible alternative in our database is the EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery).

CheckLoad requiresAnker SOLIX C1000 providesUS/NAUK/EU/AU
Continuous output 5,760 W (5,520 W @ 230V) 1,800 W Fail Fail
Start-up surge 5,760 W 2,400 W Fail Fail
Voltage 240 V / 230 V 120 V / 230 V Fail Pass
Connection NEMA 14-50P NEMA 5-20R UK/EU/AU: Type 2 EVSE · IEC 60309 32A Commando

An EVSE is a constant-current device: the vehicle draws exactly the current advertised by the J1772/NACS pilot signal, so the 5,760 W figure is both the running load and the start-up load — there is no motor inrush. That makes the calculation unusually clean. Because this charging profile is 240 V, the vehicle will not draw power from a 120 V-only receptacle at this current; the portable connector would need a Level 1 adapter and a 12 A limit instead. A full battery delivers about 0.8 kWh into the pack after inverter and on-board charger losses, worth roughly 3 miles (5 km) of driving at 3.5 mi/kWh.

As a portable power station, the Anker SOLIX C1000 integrates the LiFePO4 battery, inverter, MPPT solar controller and AC outlets in one chassis, so it can be wheeled to the load or connected to a transfer switch through its NEMA 5-20R outlet.

Compatible alternative: the EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) with the BMW i4 / iX (Flexible Fast Charger 24A) report shows the full sizing for a unit that passes all three checks.

2. Real-World Runtime by Duty Cycle

Nameplate capacity is not usable capacity. DC-to-AC conversion, battery management overhead and cell protection reduce the 1,056 Wh rating to about 898 Wh of deliverable AC energy (85% system efficiency). EV charging runs at a fixed current, so the 100% row is the realistic figure; lower rows apply only if you schedule charging in intervals.

Runtime (h) = (1,056 Wh × 0.85) ÷ (5,760 W × duty cycle)
Duty cycleAverage drawRuntime (no solar)Energy per 24 h
25% 1,440 W 37 min 34.6 kWh
50% 2,880 W 19 min 69.1 kWh
65% 3,744 W 14 min 89.9 kWh
100% 5,760 W 9 min 138.2 kWh

Even at a 50% duty cycle the battery lasts 19 min, so plan on solar, grid or generator recharging for anything longer than an evening outage. Because the inverter cannot actually run this load in North American mode, treat these numbers as an energy-budget reference for a compatible inverter of the same capacity.

3. NEC 125% Breaker & Copper Wire Gauge Sizing

NEC 210.19(A) and 210.20(A) require conductors and overcurrent devices for continuous loads — anything running three hours or more, which includes EV charging and HVAC — to be rated at 125% of the load current. For this pairing: 5,760 W ÷ 240 V = 24.0 A, × 1.25 = 30.0 A, which rounds up to the next standard NEC 240.6 size of 30 A. The conductor must be protected by that breaker (75 °C ampacity at least 30 A) and keep round-trip voltage drop at or below 3%, so longer runs are upsized.

Breaker ≥ (5,760 W ÷ 240 V) × 1.25 = 30.0 A → 30 A
Voltage drop % = (2 × L × I × R) ÷ V × 100

North America (NEC, THHN copper, 75 °C)

One-way distanceBreakerMin. copperVoltage dropNote
25 ft (7.6 m) 30 A 10 AWG 0.60% Sized by ampacity
50 ft (15.2 m) 30 A 10 AWG 1.21% Sized by ampacity
75 ft (22.9 m) 30 A 10 AWG 1.81% Sized by ampacity
100 ft (30.5 m) 30 A 10 AWG 2.42% Sized by ampacity

UK / EU / Australia (IEC 60364 / BS 7671, PVC copper, method C)

IEC-based codes size protection by design current rather than a blanket 125% multiplier: Ib ≤ In ≤ Iz. At 230 V the load draws 24.0 A (the EVSE's 24 A pilot current at 230 V), so a 25 A Type B/C MCB with RCD protection applies. In the UK, BS 7671 Section 722 additionally requires a dedicated circuit and Type A or Type B RCD for EV charge points.

One-way distanceMCBMin. cableVoltage drop
7.5 m (25 ft) 25 A 2.5 mm² 1.16%
15 m (49 ft) 25 A 2.5 mm² 2.32%
22.5 m (74 ft) 25 A 4.0 mm² 2.16%
30 m (98 ft) 25 A 4.0 mm² 2.89%

Because the current is modest, 10 AWG copper stays within the voltage-drop target all the way to 100 ft.

4. Solar Array Recharge Time Breakdown

The Anker SOLIX C1000 accepts up to 600 W of photovoltaic input. Real arrays rarely deliver nameplate output, so we apply an 80% harvest factor for MPPT conversion, cell temperature and soiling, and convert hours to days using 4.5 peak-sun-hours — a conservative annual average for the US, southern Europe and Australia (UK winters can fall below 1.5).

PV arrayReal harvest0–100% rechargeSun-days @ 4.5 PSHNet with load @ 50%
400 W 320 W 3.3 hrs 0.7 −2,560 W
600 W 480 W 2.2 hrs 0.5 −2,400 W

A typical 600 W portable array refills the battery in about 2.2 hrs of strong sun, while maxing out the 600 W input cuts that to 2.2 hrs. To fully offset the BMW i4 / iX (Flexible Fast Charger 24A) at a 50% duty cycle (2,880 W average) during daylight you need roughly 3,600 W of panels, which exceeds this unit's 600 W input limit — solar can slow the drain but not eliminate it.

5. Frequently Asked Questions

Can the Anker SOLIX C1000 run a BMW i4 / iX (Flexible Fast Charger 24A)?

Not reliably in North America — our verdict is "240V Split-Phase Required". The load needs 240 V split-phase power and the Anker SOLIX C1000 outputs 120 V only. The EcoFlow Delta Pro Ultra (1 Inverter + 1 Battery) is a compatible alternative. In UK/EU/AU 230 V mode the verdict is "Continuous Overload".

How many miles of range can the Anker SOLIX C1000 add to a BMW i4 / iX?

A full 1,056 Wh charge delivers about 0.8 kWh to the vehicle battery after inverter (85%) and on-board charger (90%) losses — roughly 3 miles at 3.5 mi/kWh. Charging at this profile is not possible on this unit without reducing current or changing voltage.

What breaker and wire size do I need to connect a BMW i4 / iX (Flexible Fast Charger 24A) to the Anker SOLIX C1000?

In the US, 5,760 W at 240 V is 24.0 A; applying the NEC 125% continuous-load rule gives 30.0 A, so use a 30 A breaker and 10 AWG copper for runs up to 25 ft (0.6% voltage drop). In 230 V markets the load draws 24.0 A, protected by a 25 A MCB on 2.5 mm² cable for runs up to 7.5 m. Receptacle: NEMA 14-50P (US) or Type 2 EVSE · IEC 60309 32A Commando (UK/EU/AU).

How long does it take to recharge the Anker SOLIX C1000 with solar panels?

With an 600 W array and an 80% real-world harvest factor, a full recharge takes about 2.2 hrs of peak sun (0.5 days at 4.5 peak-sun-hours). At its maximum 600 W solar input it drops to 2.2 hrs.

Methodology & safety note

Specifications come from manufacturer datasheets in our open dataset; ampacity and resistance values follow NEC Table 310.16 and Chapter 9 Table 8, and BS 7671 Appendix 4. Calculations assume copper conductors, 30 °C ambient and no bundling derating. Inverter-to-panel connections require a listed transfer switch or interlock to prevent back-feeding the grid. These results are an engineering estimate, not a substitute for a licensed electrician and local permit. See our methodology and safety disclaimer.

Status dots show the North American verdict: compatible, conditional, not compatible.